![Kubota M6H-101 Operator'S Manual Download Page 60](http://html1.mh-extra.com/html/kubota/m6h-101/m6h-101_operators-manual_2008852060.webp)
4.1 PM warning level and required procedures
In the regeneration inhibit mode, the buzzer starts sounding and the indicator display changes in response to the PM
level in order to prompt the operator to perform the required procedure listed in the following table.
IMPORTANT :
• Once the regeneration level has been reached, immediately perform the required procedure for
regeneration.
Interrupting the regeneration cycle or continuing operation while ignoring the warning signs may cause
DPF and engine damage.
Regeneration inhibit mode
DPF system status
Required procedure
PM warning level: 1
Buzzer: Not sounding
The regeneration indicator starts flashing.
A specific level of PM has built up in the DPF
muffler.
Continue with the operation as it is.
At PM warning levels range from 1 to 2-2, it is also possible to change DPF inhibit switch to
auto regeneration mode, then perform the regeneration.
PM warning level: 2-1
Buzzer: Sounding every 5 sec-
onds
The regeneration indicator starts flashing.
Move the tractor to a safe area, then begin
the parked regeneration cycle process.
(See Operating procedure for parked regener-
ation on page 55.)
PM warning level: 2-2
Buzzer: Sounding every 3 sec-
onds
The parked regeneration indicator starts
flashing.
PM warning level: 3
Buzzer: Sounding every 1 second
Engine output: 50%
If the parked regeneration cycle is interrupted or the tractor is continuously operated in the PM warning lev-
el 2:
The engine warning indicator starts flashing.
Immediately stop working the tractor, move
the tractor to a safe area, then begin the
parked regeneration cycle process.
(See Operating procedure for parked regener-
ation on page 55.)
If the tractor is operated further and the oper-
ator ignores the warning signs, then regener-
ation will be disabled.
The parked regeneration indicator starts
flashing.
PM warning level: 4
Buzzer: Sounding every 1 second
Engine output: 50%
If the regeneration cycle is interrupted or the tractor is continuously operated ignoring the warning signs, in
the PM warning level 3:
The engine warning indicator remains con-
stantly
“ON”
.
Immediately move the tractor to a safe place,
park it there and turn the engine
“OFF”
.
Contact your local KUBOTA Dealer.
•
At this level, do not continue to operate
the tractor; otherwise, damage may re-
sult to the DPF and engine.
OPERATING THE ENGINE
DIESEL PARTICULATE FILTER (DPF) MUFFLER
54
M6S-111,M6L-111,M6H-101
Summary of Contents for M6H-101
Page 6: ......
Page 14: ...8 M6S 111 M6L 111 M6H 101 ...
Page 23: ...SAFETY LABELS SAFE OPERATION M6S 111 M6L 111 M6H 101 17 ...
Page 24: ...SAFE OPERATION 18 M6S 111 M6L 111 M6H 101 ...
Page 25: ...SAFE OPERATION M6S 111 M6L 111 M6H 101 19 ...
Page 26: ...SAFE OPERATION 20 M6S 111 M6L 111 M6H 101 ...
Page 27: ...SAFE OPERATION M6S 111 M6L 111 M6H 101 21 ...
Page 28: ...SAFE OPERATION 22 M6S 111 M6L 111 M6H 101 ...
Page 30: ...24 M6S 111 M6L 111 M6H 101 ...