![Kubota M6H-101 Operator'S Manual Download Page 156](http://html1.mh-extra.com/html/kubota/m6h-101/m6h-101_operators-manual_2008852156.webp)
5. Checking water separator
1. When the water has collected up to the upper limit
in the water separator, the water separator indicator
on the instrument panel lights up and a warning
buzzer sounds.
(1) Water separator indicator
2. In this case, close the fuel shutoff-valve and loosen
the air plug and drain plug by several turns.
3. Allow the water to drain. When no more water
comes out and fuel starts to flow out, retighten the
air plug and drain plug.
4. Bleed the fuel system.
(See SERVICE AS REQUIRED on page 181.)
M6S-111
(1) Red float
(2) Fuel shutoff-valve
(3) Air plug
(4) Cup
(5) Drain plug
(A) [ON]
(B) [OFF]
(C) “FUEL”
(D) “UPPER LIMIT”
(E) “WATER”
M6L-111
(1) Red float
(2) Fuel shutoff-valve
(3) Air plug
(4) Cup
(5) Drain plug
(A) [ON]
(B) [OFF]
(C) “FUEL”
(D) “UPPER LIMIT”
(E) “WATER”
M6H-101
(1) Red float
(2) Fuel shutoff-valve
(3) Air plug
(4) Cup
(5) Drain plug
(A) [ON]
(B) [OFF]
(C) “FUEL”
(D) “UPPER LIMIT”
(E) “WATER”
IMPORTANT :
• If water is drawn through to the fuel pump,
extensive damage will occur.
NOTE :
• When the red float reaches near the upper
limit level, start from step 2 in the above
procedure to drain water from the water
separator.
6. Checking engine oil level
WARNING
To avoid personal injury or death:
• Be sure to stop the engine before checking the
oil level.
PERIODIC SERVICE
DAILY CHECK
150
M6S-111,M6L-111,M6H-101
Summary of Contents for M6H-101
Page 6: ......
Page 14: ...8 M6S 111 M6L 111 M6H 101 ...
Page 23: ...SAFETY LABELS SAFE OPERATION M6S 111 M6L 111 M6H 101 17 ...
Page 24: ...SAFE OPERATION 18 M6S 111 M6L 111 M6H 101 ...
Page 25: ...SAFE OPERATION M6S 111 M6L 111 M6H 101 19 ...
Page 26: ...SAFE OPERATION 20 M6S 111 M6L 111 M6H 101 ...
Page 27: ...SAFE OPERATION M6S 111 M6L 111 M6H 101 21 ...
Page 28: ...SAFE OPERATION 22 M6S 111 M6L 111 M6H 101 ...
Page 30: ...24 M6S 111 M6L 111 M6H 101 ...