2. Auxiliary port operation [high-flow model only]
The AUX port switch is used to operate hydraulic attachment such as hammers.
2.1 Selecting the action modes
The AUX port has been factory-set to three action modes. You can select one of them. Up to six action modes can be
preset.
Each time the AUX port switch is pressed, the action modes change over one after another. And the icon and action
mode number on the screen change accordingly.
• When setting flow volume is within the standard flow range, the indicator " " lights up.
• When setting flow volume is within the High-Flow range, the indicator " " blinks.
(1) Indicator
(2) AUX port switch
[a] Mode 0 (AUX disable (normal
screen))
[b] Mode 1
[c] Mode 2
(a) No lighting
(b) Lighting
(c) Blinking
(A) No activation
(B) Standard flow volume
(C) Max flow volume
•
Checking the setting volume
Pressing the display selector switch when the action mode number
“AUX-1”
is displayed on the screen, the screen
will vary per second.
(1) Memory number
(2) Lever side (right side)
(3) Flow volume
(4) Lever side (left side)
NOTE :
– When turning the starter key to the [RUN] position, the action mode will return to the last action mode
used.
AUXILIARY HYDRAULIC
HOW TO USE THE AUXILIARY HYDRAULIC CONTROL
70