3. From behind the dust-cover, remove foreign matter
from the evacuator valve.
(1) Evacuator valve
(2) Dust cover
(A) Clean from behind
IMPORTANT :
• Failure to clean the evacuator valve may
shorten the air cleaner element's service life.
EVERY 250 SERVICE HOURS
Carry out all 50 hour servicings at the same time.
1. Checking the radiator hoses and
the clamps
Check the water hoses for proper connection.
WARNING
To avoid personal injury or death:
• Wait long enough for the radiator coolant to
cool down.
Carry out the check of the radiator hoses and the
clamps of every 250 hours or every six months,
whichever comes first.
1. Tilt the radiator.
2. If the hose clamps become loose or water leaks,
tighten the hose clamps properly.
3. If the radiator hoses become swollen, aged, or
cracked, replace the radiator hoses and re-tighten
the hose clamps properly.
(1) Radiator hose
(2) Hose clamps
2. Checking the fuel line and the
intake air line
1. Check to see that all fuel lines and hose clamps are
tightened and not damaged.
EVERY 250 SERVICE HOURS