16 Input modes: Frequency meter
Function
Diagram
PNP: Count on rising edge
NPN: Count on falling edge
A
Inp A: Frequency input
Inp B: no function
AsubB
Inp A: Frequency input 1
Inp B: Frequency input 2
Formula:
A - B
AaddB
Inp A: Frequency input 1
Inp B: Frequency input 2
Formula:
A + B
Quad
A 90° B
Inp A: Frequency input 1
Inp B: Reverse direction
A / B
Inp A: Frequency input 1
Inp B: Frequency input 2
Formula:
A / B
(A-B)/A
Inp A: Frequency input 1
Inp B: Frequency input 2
Formula:
(A – B)/A x100