9.3 Frequency Ratio Settings
When using two sensors with different number of impulses, or in case of mechanical
gear transmission ratio between both encoders, the higher one of the two frequencies
must be adjusted to the lower one by corresponding setting of the scaling factors.
Accurately calculated values are better than experimental results.
No.
Parameter
Remark
019
„Multiplier 1“
Proportional factor for sensor 1
For SMC1.3, this parameter must be set to value 1!
020
„Divisor 1“
Reciprocal factor for Sensor 1
For SMC1.3, this parameter must be set to value 1!
031
„Multiplier 2“
Proportional factor for sensor 2
For SMC1.3, this parameter must be set to the value 1!
032
„Divisor 2“
Reciprocal factor for Sensor 2
For SMC1.3, this parameter must be set to value 1!
In this example,
the frequency 2
is greater than
frequency 1 by a
factor of 2.
For adjustment,
parameter
"Divisor 2" can
be set to 2.
By this scaling
procedure of
frequency 2,
internally both
calculated
frequencies are
approximately
equal and the
calculated
frequency ratio is
close to 0.
Summary of Contents for SMC1.3
Page 44: ...R60047 0001 Index 2 DE Seite 44 120 8 2 Montage Demontage...
Page 49: ...R60047 0001 Index 2 DE Seite 49 120...
Page 117: ...R60047 0001 Index 2 DE Seite 117 120 20 Zertifikat...
Page 118: ...R60047 0001 Index 2 DE Seite 118 120...
Page 119: ...R60047 0001 Index 2 DE Seite 119 120...
Page 163: ...R60047 0002 Index 2 EN page 43 115 8 2 Mounting Dismounting...
Page 168: ...R60047 0002 Index 2 EN page 48 115...
Page 234: ...R60047 0002 Index 2 EN page 114 115 20 Certificate...