![Kübler SMC1.3 Safety Manual Download Page 167](http://html1.mh-extra.com/html/kubler-0/smc1-3/smc1-3_safety-manual_2008430167.webp)
R60047.0002 - Index 2
EN – page 47 / 115
9 Setup
In order to ensure proper functionality, the parameters must be set appropriate values.
This section describes the most important parameters, which have to be set or checked
in either case.
9.1
Operational Mode Settings
The Parameters "Op-Mode 1" and Op-Mode 2 "are determined by the used encoder.
Notes on the encoder connection and the resulting "OP Modes" for Sensor 1 and sensor
2 can be read in the chapter Operating Modes SMC2.4 or SMC1.3.
No. Parameter
Remark
016 „Op-Mode 1“ See chapter “Operating modes SMC2.4” or “Operating
modes SMC1.3”.
028 „Op-Mode 2“ See chapter “Operating modes SMC2.4” or “Operating
modes SMC1.3”.
At SMC1.3 "Op-Mode 2" must be set equal to "Op-Mode 1"!
9.2
Direction Settings
In order to define the directions, the machine must move resp. turn in its working
direction. As a first step,
must be selected from the button bar of the
operator screen.
The corresponding frequencies of Sensor 1 and Sensor 2 will then be indicated in the
Monitor field. In case of negative frequency values, the direction must be changed by
using the associated “Direction “ register in the parameter field of the corresponding
sensor menu.
No. Parameter
Remark
018 „Direction 1“
Select direction of rotation
030 „Direction 2“
Select direction of rotation
At SMC1.3 " Direction 2" must be set equal to " Direction 1"!
Summary of Contents for SMC1.3
Page 44: ...R60047 0001 Index 2 DE Seite 44 120 8 2 Montage Demontage...
Page 49: ...R60047 0001 Index 2 DE Seite 49 120...
Page 117: ...R60047 0001 Index 2 DE Seite 117 120 20 Zertifikat...
Page 118: ...R60047 0001 Index 2 DE Seite 118 120...
Page 119: ...R60047 0001 Index 2 DE Seite 119 120...
Page 163: ...R60047 0002 Index 2 EN page 43 115 8 2 Mounting Dismounting...
Page 168: ...R60047 0002 Index 2 EN page 48 115...
Page 234: ...R60047 0002 Index 2 EN page 114 115 20 Certificate...