Manual - analog (U/I)
Sendix M3661 / M3681
Sendix M3661R
Sendix M5861
ENG - 5 (R60722.0002 - Index 3)
english
1.6 Supported standards and functions
8.M36X1.XX3X.3X12 / 8.M3661R.XX3X.3X12 / 8.M5861.XXXX.XX12:
Output: 4 … 20mA
Resolution:
12
bits
Max. measuring range: 65536 revolutions
Min. measuring range: 22.5°
Zero point display: 0 … 1°
8.M36X1.XX4X.4X12 / 8.M3661R.XX4X.4X12 / 8.M5861.XXXX.XX12:
Output: 0 … 10 VDC
Resolution:
12
Bit
Max. measuring range: 65536 revolutions
Min. measuring range: 22,5°
Zero point display: 0 … 1°
8.M36X1.XX4X.5X12 / 8.M3661R.XX4X.5X12 / 8.M5861.XXXX.XX12:
Output: 0 … 5 VDC
Resolution:
11
bits
Max. measuring range: 65536 revolutions
Min. measuring range: 22.5°
Zero point display: 0 … 1°
1.7 Optional functions
• Measuring range scaling via scaling inputs (max. 10,000 cycles)
• Limit switch function
• Direction of rotation: CCW (is factory-set and cannot be modified by the user.)