Manual - analog (U/I)
Sendix M3661 / M3681
Sendix M3661R
Sendix M5861
ENG - 11 (R60722.0002 - Index 3)
english
4.5 Limit switch function (optional)
With the limit switch function, the output signal does not remain at the last final value, but it makes a defined jump. This signal
jump can be used by a control as a limit switch. The output levels of the limit switches are factory-set.
Scalable variant with limit switch function
5. Abbreviations used
CW
Direction of rotation: clockwise looking at the shaft.
CCW
Direction of rotation: counterclockwise looking at the shaft.
MT
Revolution counter.
ST
Angle information within a revolution.
(n
≤
16)
0°
2
n
revol.
Teach
point 2
Roll-
over
Teach
point 1
version
0 ... 5
versi
on 4
... 2
0 mA
vers
ion
0 ...
10
22 mA / 9,75 V
20 mA / 9,5 V
0 V
0,5 V
0,25 V
4 mA
3,6 mA
4,75 V
4,5 V
no reference point display!
Limit switch function
version
limit switch low
limit switch high
0 ... 10 V
0 ... 5 V
4 ... 20 mA
0,25 V
0,25 V
3,6 mA
9,75 V
4,75 V
22,0 mA
Factory-set measuring range
2
4
revolutions with roll-over