EN - page 12 (R60953.0009 3)
3. Technical description
The technical specifications for the PSU01 (Evaluation Unit + sensor) are described below.
3.1 Position Supervisor Unit (Evaluation Unit)
Feature
Value
Standard references
EN81-20, EN81-50, EN81-21
Housing material
Plastic
Housing dimensions
70 mm (H) x 95 mm (L) x 30 mm (W)
Interfaces
2 x CAN (internal and public) , 1 x SSI (optional)
Protocol
Internal: proprietary, public: CANopen, SSI: 2 x 25 bit with
PFB, grey code, MSB-first
Connection type
picoMAX
®
eCOM 3.5, 7.5 (connection and chapter 5)
Ambient operating temperature
From -5°C to +55°C
Storage temperature
From -10°C to +70°C
Humidity
< 90% (non-condensing)
Air pressure
800 - 1013 hPa (up to 2000 m over sea level)
Service life
20 years
Degree of protection
IP00 (min. IP20 when installed in the switching cabinet)
Supply voltage
24 VDC low-voltage PELV
Power
< 10 watts
Maximum distance to the encoder
100 m (internal CAN bus)
Deactivation time / system response
time
< 25 ms (incl. relay switching time)
Maximum number of floors
200
All lines and trailing cables must be manufactured with dual insulation
or mechanically protected according to EN81-20 5.10.6.
In particular, make sure that they are routed without any short circuits.