3 Product Description
Kübler Group
34 - EN
BA Ants LES02 - R60073.0009 - 02
• The measured position is not evaluated. This requires a safe evaluation unit or control that
will be able to fulfill various position-dependent safety functions.
• In the event of an error, the measuring system sends no longer position data, but only error
codes. Therefore, the sending of a position within a certain time is not guaranteed. The ab-
sence of position data must be detected and evaluated by an external evaluation unit.
• The measuring system in no way actively intervenes in the elevator system. It is purely a pos-
ition sensor.
• The scope of the measuring system is not to measure lengths. Lengths vary in particular be-
cause of the temperature and other influencing factors.
3.4 Technical Data
NOTICE
Observe the configuration
The performance characteristics and the mechanical design of the
product depend on the selected configuration (according to order
code).
Extracts of the main technical data are listed below. All other characteristic values can be found
in the corresponding product data sheets.
3.4.1 Sensor
Mechanical characteristics sensor
Operating temperature
-10 °C … +70 °C [14 °F … 158 °F]
Storage temperature
-15 °C … +80 °C [5 °F … 176 °F]
Protection level according to EN 60529 IP54
Air humidity
< 90 % (non-condensing)
Installation height
< 2000 m [6562 ft]
Material Housing
Aluminum
Weight
appr. 0,55 kg [19.40 oz]
Maximum measuring length
392 m [1286 ft]
Maximum speed
certified
functional
8 m/s [26.25 ft/s]
12 m/s [39.37 ft/s]
Resolution
certified
functional
1 mm
[0.5 mm]
Accuracy
± 1 mm
Summary of Contents for Ants LES02
Page 70: ...4 Installation K bler Group 70 FR BA Ants LES02 R60073 0009 02 27021597914791691...
Page 96: ...4 Installazione K bler Group 96 IT BA Ants LES02 R60073 0009 02 27021597914791691...
Page 122: ...4 Instalaci n K bler Group 122 ES BA Ants LES02 R60073 0009 02 27021597914791691...
Page 138: ...4 K bler Group 138 ZH CHS BA Ants LES02 R60073 0009 02 4 4 1 RMA 153 4 1 1...
Page 154: ...Step by Step Installation K bler Group 154 BA Ants LES02 R60073 0009 02 a b...
Page 155: ...K bler Group Step by Step Installation BA Ants LES02 R60073 0009 02 155 c d...
Page 156: ...Step by Step Installation K bler Group 156 BA Ants LES02 R60073 0009 02 e f...
Page 157: ...K bler Group Step by Step Installation BA Ants LES02 R60073 0009 02 157 g h...
Page 158: ...Step by Step Installation K bler Group 158 BA Ants LES02 R60073 0009 02 i j...
Page 159: ...K bler Group Notizen Notes...