R60726.0002
–
Index 6b
EN - page 38
5.16
Analog Out Menu
This menu defines the basic settings of the analog output. This function is only available
for devices with option Analog Output.
ANALOG SOURCE
This parameter defines the reference source for the Analog Output
0 INPUT 1
the reference source is input 1
1 INPUT 2
the reference source is input 1
2 LINKAGE 1
–
2
the reference source is the result of the linking of input1 and
input 2
3 INPUT 1 TOTAL
the reference source is input 1 with totalization
4 INPUT 2 TOTAL
the reference source is input 1 with totalization
5
LINKAGE TOTAL
the reference source is the result of the linking of input1 and
input 2 with totalization
6 IO LINK VALUE 1
the reference source is the process data out value 1 sent by the
IO-Link master
7 IO LINK VALUE 2
the reference source is the process data out value 2 sent by the
IO-Link master
8 MINIMUM VALUE 1
minimum value, the reference source is input 1
9 MAXIMUM VALUE 1
maximum value, he reference source is input 1
10 MINIMUM VALUE 2
minimum value, the reference source is input 2
11 MAXIMUM VALUE 2
maximum value, he reference source is input 2
The totalization depends on the operation mode. See chart in chapter IN 1 Totalization.
ANALOG FORMAT
This parameter defines the output characteristics. The analogue output is proportional to the
display value.
With setting ANALOG FORMAT (-
10 …
+10 V) in MODE COUNTER the polarity of the analog output
depends on the polarity of the display value.
0
-
10…10V
-10
… +10 V
1
0…20
MA
0 … 20 mA
2
4…20
MA
4 … 20 mA
ANALOG START
This parameter defines the start value of the analog conversion. This start value is corresponding
to the display value for an analog output of 0 V or 0/4 mA.
-99999999
Smallest start value
0
Default value
+99999999
Highest start value
ANALOG END
This parameter defines the end value of the analog conversion. This end value is corresponding to
the display value for an analog output of (+/-) 10 V or 20 mA.
-99999999
Smallest end value
10000
Default Wert
+99999999
Highest end value