5
Please observe protection
note ISO 16016.
Drawn:
2019-10-23 Pz/Str
Replacing:
KTR-N dated 2017-01-02
Verified:
2019-11-04 Pz
Replaced by:
•
Inspect distances between fan and protective grid (see chapter 8.3).
•
Inspect the individual components of the device for electrically conductive connections (including the
grounding cable connection).
•
The motor temperature has to be inspected with the device operating.
It must not exceed the temperature class specified in the type label (see illustration 12).
•
The bearings of the motors are permanently lubricated.
Re-lubrication is not possible. Please observe the service life of the motor bearing as per
the data sheet of the motor manufacturer.
The bearings must be inspected, maintained and replaced, if necessary, as per the
specifications of the motor manufacturer.
We recommend to store major spare parts on site to ensure the readiness for use of the machine in case if a
cooler fails.
Contact addresses of the KTR partners for spare parts and orders can be obtained from the KTR homepage at
www.ktr.com.
KTR does not assume any liability or warranty for the use of spare parts and accessories
which are not provided by KTR and for the damages which may incur as a result.
6
Maintenance and service
7
Spares inventory, customer service addresses