WORK 4
37
4.27
Ascertaining that the discharge plug is de-energized
Warning
Risk of injury
The measuring points could be live.
–
Use personal protective clothing and comply with the safety measures.
Condition
The KTM PowerPack has been removed.
309699-10
Main work
–
Prepare the special tool for measurement.
AVL DITEST HV Safety 2000 (70029068000)
–
Start software
HV Safety
.
–
Select
"Zero-potential"
.
–
Follow the instructions in the
HV Safety
Owner's Manual.
Finishing work
–
Mount the protection cap.
4.28
Performing an equipotential bonding check (KTM PowerPack installed)
Warning
Risk of injury
The measuring points could be live.
–
Use personal protective clothing and comply with the safety measures.
Condition
The KTM PowerPack has been removed.
309699-10
–
Prepare the special tool for measurement.
AVL DITEST HV Safety 2000 (70029068000)
–
Start software
HV Safety
.
–
Select
"Equipotential bonding check"
.
–
Follow the instructions in the
HV Safety
Owner's Manual.
4.29
Performing an equipotential bonding check (KTM PowerPack installed)
Warning
Risk of injury
The measuring points could be live.
–
Use personal protective clothing and comply with the safety measures.
Condition
The KTM PowerPack has been removed.