INSULATION MEASUREMENT 5
15
310408-51
–
Measure the resistance between the specified points.
High-voltage plug for KTM PowerPack
FV
pin
1
–
High-
voltage plug for KTM PowerPack
FV
pin
gnd
Value as per
HV Safety
» If the specified value is not reached:
–
Contact KTM customer service.
–
Secure the KTM PowerPack in the transport and quar-
antine box, if necessary.
Transport system (70029020000)
310407-51
–
Measure the resistance between the specified points.
High-voltage plug for KTM PowerPack
FV
pin
2
–
High-
voltage plug for KTM PowerPack
FV
pin
gnd
Value as per
HV Safety
» If the specified value is not reached:
–
Contact KTM customer service.
–
Secure the KTM PowerPack in the transport and quar-
antine box, if necessary.
Transport system (70029020000)
5.2
Performing an insulation measurement on the discharge plug
Warning
Risk of injury
The measuring points could be live.
–
Use personal protective clothing and comply with the safety measures.
Condition
The KTM PowerPack has been removed.
–
Prepare the special tool for measurement.
AVL DITEST HV Safety 2000 (70029068000)
–
Start software
HV Safety
.
–
Select
"Insulation measurement"
.