04/SHOCK ABSORBER, SWINGARM
55
8.20
Bleeding and filling the damper
Info
Before working with the vacuum pump, be sure to read the operating instructions carefully.
Completely open the adjusters of the rebound and compression damping.
201286-10
–
Remove the screw of the filling port.
–
Install adapter
on the damper.
Info
Tighten only hand-tight, without the use of tools.
–
Connect the adapter
to connector
of the vacuum pump.
Vacuum pump (T1240S) (
–
Clamp the damper with soft jaws or hold it as shown in the photo.
Info
Clamp the damper only lightly.
The filling port must be at the highest point.
The piston rod slides in and out during filling - do not hold it tight with your
hand!
200271-10
–
Place the control lever as shown in the photo.
The
External tank
control lever is on
Closed
,
Damper
on
Vacuum
,
and
Oil reservoir
on
Vacuum
.
–
Operate the
On/Off
switch
.
The vacuum pump process starts.
Pressure gauge
falls to the specified value.
< 0 bar
The vacuum gauge
falls to the specified value.
4 mbar
201285-10
–
Measure distance
between the floating piston and reservoir hole with the special
tool.
Depth micrometer (T107S) (
The floating piston is positioned all the way at the bottom.
200267-10
–
When the vacuum pressure gauge reaches the specified value, turn the
Oil reser-
voir
control lever
to
Equalize pressure
.
Guideline
4 mbar
The pressure gauge rises to the specified value.
0 bar
Summary of Contents for 690 Enduro AUS 2010