39/IGNITION SYSTEM
170
26
39/IGNITION SYSTEM
26.1
Checking the generator
–
Remove the fuel tank. (
600408-10
–
Disconnect the electric plug-in connector
of the stator coil.
600407-10
–
Using a multimeter, measure the stator coil on connector
.
Stator coil - resistance
black - black
0.0… 1.0
Ω
Ground - black
∞
» If the displayed value does not correspond to the nominal value:
–
Change the stator.
26.2
Checking the ignition pulse generator
–
Remove the fuel tank. (
600432-10
–
Disconnect the plug-in connector of the ignition pulse generator coil to the CDI
unit.
–
On ignition pulse generator
, use a multimeter to measure the resistance of the
ignition pulse generator coil.
Pulse generator
red - green
80… 120
Ω
Ground - red
∞
» If the displayed value does not correspond to the nominal value:
–
Change the ignition pulse generator.
26.3
Checking the ignition coil
Condition
All plug connectors must be in corrosion-free condition and the plug-in connectors
must be tight-fitting.
–
Remove the radiator spoiler. (
–
Remove the spark plug connector.
600456-10
–
Use a multimeter to measure the primary coil value.
Primary coil
ground - ignition coil input at:
20
°C (68
°F)
0.25… 0.35
Ω
» If the measured value differs from the nominal value:
–
Change the ignition coil.