background image

-1- 

 

 

 

 

KGS-2422-TG

 

 

Managed 26-Port Modular Gigabit Ethernet 

Switches with 10G Uplink Support

 

 

Installation Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DOC.190109A 

Summary of Contents for KGS-2422-TG Series

Page 1: ... 1 KGS 2422 TG Managed 26 Port Modular Gigabit Ethernet Switches with 10G Uplink Support Installation Guide DOC 190109A ...

Page 2: ...rves the right to revise this documentation and to make changes in content from time to time without obligation on the part of KTI Networks Inc to provide notification of such revision or change For more information contact United States KTI Networks Inc P O BOX 631008 Houston Texas 77263 1008 Phone 713 2663891 Fax 713 2663893 E mail kti ktinet com URL http www ktinet com International Fax 886 2 2...

Page 3: ...nterference and 2 This device must accept any interference received including the interference that may cause undesired operation CE NOTICE Marking by the symbol indicates compliance of this equipment to the EMC directive of the European Community Such marking is indicative that this equipment meets or exceeds the following technical standards EMC Directive of 2014 30 EU EN 55032 CISPR 32 EN 61000...

Page 4: ...n 23 2 9 Making UTP Connections 24 2 10 Making SFP Fiber Connection 24 2 11 Making Fixed Duplex Fiber Connection 25 2 12 Making Fixed Bi Di Bi Directional Fiber Connection 27 2 13 Making 10G SFP Connections 28 2 14 LED Indication 30 2 15 Making Console Connection 31 3 Managing the Switch 32 3 1 IP Address Password 32 3 2 Configuring IP Address via console and telnet CLI 32 3 3 Configuring Local Au...

Page 5: ... 5 3 7 SNMP MIBs 40 ...

Page 6: ...ASE SFP slots on the back rear panel The SFP slots can be installed with 10GBASE optical fiber transceivers for high bandwidth fiber connection They are used as uplink ports to the backbone networks They also can be used as a high bandwidth inter connection between two switches and support full wire speed forwarding between two switches The switches support Telnet CLI Web GUI SNMP and console CLI ...

Page 7: ... flow control for full duplex and backpressure for half duplex Support console and in band Web Telnet SSH HTTPS SNMP interfaces for switch management Support configurable maximum frame length from 1518 up to 10056 jumbo frame Support port based 802 1Q tag based VLAN and private VLAN Provide QoS function Support port bandwidth control for ingress and egress Support packets storm control function fo...

Page 8: ...andwidth shaper DiffServ RFC2474 DSCP based classification and remarking Tag based remarking Port scheduler mode for egress queue Layer2 Auto MAC address learning and ageing Static MAC address filtering 802 1Q VLAN Private VLAN Port Isolation MAC based VLAN Protocol based VLAN IP subnet based VLAN VLAN trunking LAN Trunking Multiple Registration Protocol MRP IEEE 802 1ad Provider Bridge Native or ...

Page 9: ...ing users that wish to manage the switch TACACS Accounting Web CLI Authentication User Authorization Levels for CLI and Web management Web based Authentication Authorization 15 user levels ACLs for filtering policing port copy Access Control Lists for filtering policing or port copy IP source guard Access Control List for L2 L3 protocol filtering ingress rate limit port copy Management DHCP Client...

Page 10: ... 10 SNMP v1 v2c v3 Agent RMON Group 1 2 3 9 SNMP trap group Link Layer Discovery LLDP LLDP MED Cisco Discovery filtering CDP sFlow Software Download via Web Configuration download and upload SNMP MIBs ...

Page 11: ... Model Front Panel Rear Panel Power Input AC powered model DC powered model 1 3 Optional 8 port Modules Module Part No Image Specifications 8GT 8 10 100 1000 copper ports 8 RJ 45 jacks 8GX 8 port 100 1000 SFP module 8 dual speed SFP slots Supports standard 100M or 1000M SFP optical fiber transceivers ...

Page 12: ...ivers support 100Mbps Options MMF 2km SMF 20km 8FM xxx 6 fixed 100M fiber ports with 6 duplex SC transceivers supporting 100Mbps 2 10 100 1000 copper ports 2 RJ 45 Fiber options MMF 2km SMF 20km 8FX T 8 fixed 100M fiber ports 8 duplex ST transceivers support 100Mbps and MMF 2km 8FM T 6 fixed 100M fiber ports with 6 duplex ST transceivers supporting 100Mbps and MMF 2km 2 10 100 1000 copper ports 2 ...

Page 13: ...0 Rx1550 SMF 20km Tx1550 Rx1310 SMF 20km 1 3 1 Optional Module Table Module Part No 10 100 1000M Copper ports 100 1000M pluggable SFP Fixed 100M Fiber 8GT 8 RJ 45 8GX 8 SFP 8G4 4 RJ 45 4 SFP 8FX T 8 ST for MMF 2km 8FX C 8 SC for MMF 2km 8FX SL2 8 SC for SMF 20km 8FX W3520 8FX W5320 8 BiDi SC for single SMF 20km 8FM SL2 2 RJ 45 6 SC for SMF 20km 8FM C 2 RJ 45 6 SC for MMF 2km 8FM T 2 RJ 45 6 ST for...

Page 14: ... Full Half duplex Network cable Cat 5 UTP Dual speed SFP Slots Compliance IEEE 802 3z 1000BASE SX LX mini GBIC IEEE 802 3u 100BASE FX Connectors SFP slot supports optional both 100M and 1000M SFP type fiber transceivers Configuration options Auto negotiation 1000Mbps Full duplex Forced 100Mbps Full duplex Software configurable Network cables MMF 50 125 m 60 125 m SMF 9 125 m Eye safety IEC 825 com...

Page 15: ...esses Table 32K entries Forwarding filtering Non blocking full wire speed Switching technology Store and forward Maximum packet length 10240 bytes Jumbo frame support Packet Buffer 16Mbit Flow control IEEE 802 3x pause frame base for full duplex operation Back pressure for half duplex operation VLAN function Port based VLAN and IEEE 802 1Q Tag based VLAN VLAN support 4096 VLANs IEEE 802 1Q Aggrega...

Page 16: ...x Mechanical Dimension base 443 x 245 x 43 mm WxDxH Housing Enclosed metal Mounting Desktop mounting 19 rack mounting Environmental Operating Temperature Typical 5o C 50o C Storage Temperature 25o C 85o C Relative Humidity 10 90 non condensing Electrical Approvals FCC Part 15 rule Class A CE EMC Directive of 2014 30 EU Safety LVD IEC60950 1 ...

Page 17: ... conditions occur unplug the product from the electrical outlet and replace the part or contact your trained service provider The power cable extension cable or plug is damaged An object has fallen into the product The product has been exposed to water The product has been dropped or damaged The product does not operate correctly when you follow the operating instructions Do not push any objects i...

Page 18: ... steps to install a module are 1 Unscrew and open the cover of the module slot 2 Insert the module into the slot until it is plugged on the slot connector properly 3 Screw the module on the front panel of the base chassis securely ...

Page 19: ... steps to remove an installed module from a base chassis are 1 Unscrew the module first 2 Loosen two screw brackets and pull them out as shown below 3 Use the brackets as handles to pull the module out from the module slot connector ...

Page 20: ...nd adequate ventilation around the device Do not place heavy objects on the device Rack Mounting Two 19 inch rack mounting brackets are supplied with the switch for 19 inch rack mounting The steps to mount the switch onto a 19 inch rack are 1 Turn the power to the switch off 2 Install two brackets with supplied screws onto the switch as shown in figure below After bracket mounting ...

Page 21: ...n 2 6 Applying AC Power Supply If the purchased switch is with AC power input one AC power cord which meets the specification of your country of origin was supplied in package Before installing AC power cord to the switch make sure the AC power is OFF and the AC power to the power cord is turned off ...

Page 22: ...2 2 7 Applying DC Power Supply If the purchased switch is with DC power input the power connector is shown below DC power input specifications Receptacle Screw type terminal block Operating Voltages 40 60VDC or 40 60VDC Power Consumption 48W max Contacts Vdc input Vdc input Protective earth Connected chassis and isolated with Vdc Vdc Important Note 1 For a PERMANENTLY CONNECTED SWITCH EQUIPMENT a ...

Page 23: ...g problem is suspected it is useful to push the button to reset the switch without turning off the power Check whether the network is recovered The button can also be used to restore the software configuration settings to factory default values The operations are Operation Function Press the button for more than five seconds until Restore factory default settings all LEDs blink Then release button...

Page 24: ...e speed and duplex configuration with the connected device automatically when each time a link is being established If the connected device is also auto negotiation capable both devices will come out the best configuration after negotiation process If the connected device is incapable in auto negotiation the switch will sense the speed and use half duplex for the connection Port Configuration Mana...

Page 25: ...s seated securely in the slot place the bail in lock position Connecting Fiber Cables LC connectors are commonly equipped on most SFP transceiver modules Identify TX and RX connector before making cable connection Plug in the cables as shown below Make sure RX to TX connection rule is followed between two ends of the connected cable 2 11 Making Fixed Duplex Fiber Connection The following figure il...

Page 26: ...nnectors is also available in the listed optional modules Identify TX and RX connector before making cable connection Plug in the cables as shown below Make sure RX to TX connection rule is followed between two ends of the connected cable ...

Page 27: ...The following figure illustrates an example of fixed Bi Di Bi directional fiber port with one SC connector A Bi Di port supports single fiber connection It uses different optical wavelengths for transmission and receiving individually as figure illustrated below ...

Page 28: ...ary standards More proprietary transceivers which support longer connected distance and different optical specifications are available in the market Consult your dealer for more information 1000BASE X SFP Fiber Transceivers The following table lists the IEEE 802 3 standard 1000BASE X specifications Standard Wavelength Fiber Distance 1 1000BASE SX 850nm MMF 550m 1000BASE LX 1310nm SMF 10km 1000BASE...

Page 29: ...s The SFP Passive DAC cable is a high performance cost effective solutions for 10Gb Ethernet and 10G Fiber Channel applications SFP Passive DAC cable enables hardware manufacturers and data center operators to achieve high port density configurability and utilization at a very low cost and with reduced power requirements SFP Active Optical Cable AOC AOC is one of the forms of DAC cable It integrat...

Page 30: ...switch is initialized completely and normal 1000M Port speed status Green ON 1000Mbps is selected OFF 100Mbps or 10Mbps is selected Link Act Port link status Green ON Port link is established No traffic BLINK Port link is up and there is traffic OFF Port link is down 25 26 Port25 26linkstatus Green ON 10Gbps port link is established No traffic BLINK 10Gbps port link is up and there is traffic Yell...

Page 31: ...RXD Pin 3 TXD Pin 5 GND Pin 1 4 6 9 NC Use RS232 null modem without handshaking to connect the console port to PC s DB9 COM port as follows Console Pins COM Port Pins Pin 2 RXD Pin 3 TXD Pin 3 TXD Pin 2 RXD Pin 5 GND Pin 5 GND Baud Rate Information Baud rate 115200 Data bits 8 Parity none Stop bit 1 Flow control disabled ...

Page 32: ...Fixed Username admin Privilege level 15 No password The switch supports local authentication instead of RADIUS authentication with factory defaults No password is required with factory default However the password is used for local authentication in accessing to the switch via console telnet and Http web based interface For security reason it is recommended to change the default settings for the s...

Page 33: ... via console and telnet CLI Example config username michael privilege 15 password unencrypted 12345 Remark 1 The username example is Michael and the password is unencrypted 12345 2 Michael is given privilege 15 the highest level 3 The username and password is used as local authentication for CLI and web UI Since default username admin can not be deleted and not protected with password it is necess...

Page 34: ...ss is used as URL for the browser software to search the device URL http 192 168 0 2 Login to the switch When browser software connects to the switch successfully a Login screen is provided for you to login to the device as the left display below Enter the following default values in the login page Fixed User Name admin No password is required Click OK to login into the switch ...

Page 35: ...67295 seconds Current Lease For DHCP interfaces with an active lease this column shows the current interface address as provided by the DHCP server Address The IPv4 address of the interface in dotted decimal notation If DHCP is enabled this field configures the fallback address The field may be left blank if IPv4 operation on the interface is not desired or no DHCP fallback address is desired Mask...

Page 36: ...of the device But others value need to refer to each group privilege level User s privilege should be same or greater than the group privilege level to have the access of that group By default setting most groups privilege level 5 has the read only access and privilege level 10 has the read write access And the system maintenance software upload factory defaults and etc need user privilege level 1...

Page 37: ... of the device But others value need to refer to each group privilege level User s privilege should be same or greater than the group privilege level to have the access of that group By default setting most groups privilege level 5 has the read only access and privilege level 10 has the read write access And the system maintenance software upload factory defaults and etc need user privilege level ...

Page 38: ...e to configure password for admin user 3 5 Reference Manuals for Web Console Telnet Management The following operation manuals are also provided separately for Console Telnet and Web management Operation manual telnet console management xxxxxx doc Operation manual web management xxxxx doc The manuals describe the detailed commands and information ...

Page 39: ...SNMP command group to configure SNMP related settings config snmp server access access configuration community Set the SNMP community contact Set the SNMP server s contact string engine id Set SNMP engine ID host Set SNMP host s configurations security to group security to group configuration trap Set trap s configurations user Set the SNMPv3 user s configurations version Set the SNMP server s ver...

Page 40: ...jects for network interface sub layers RFC 3411 SNMP Management Frameworks RFC 3414 User Based Security Model USM MIB module for the SNMP User based Security Model RFC 3415 View Based Access Control Model VACM MIB module for the View based Access Control Model for SNMP RFC 3635 EtherLike MIB MIB module to describe generic objects for Ethernet like network interfaces RFC 3636 802 3 Medium Attachmen...

Page 41: ...MIB MIBs defined in 802 1AB IEEE 802 1X Port Access Entity PAE MIB MIBs defined in 802 1X IEEE 802 1 Q BRIDGE MIB The VLAN Bridge MIB module for managing Virtual Bridged LANs as defined byIEEE 802 1Q 2005 IEEE 802 3ad Link Aggregation LAG MIB MIBs defined in 802 3ad TIA 1057 LLDP Media Endpoint Discovery MED MIB The LLDP MIB extension module for TIA TR41 4 Media Endpoint Discovery information Priv...