![KSB WKTR Installation & Operating Manual Download Page 53](http://html1.mh-extra.com/html/ksb/wktr/wktr_installation-and-operating-manual_2006704053.webp)
What
Checks
Maintenance intervals
Maintenance work
Temperature measuring
instruments
14)
Perfect condition and
functioning
Switching points
Vibration measurement
14)
Perfect condition and
functioning
Shaft bearing monitoring
14)
Perfect condition and
functioning
If there are any deviations, proceed in accordance with the Trouble-shooting table.
(
7.2.3 Lubrication and lubricant change
DANGER
Excessive temperatures as a result of bearings running hot or defective bearing seals
Explosion hazard!
Fire hazard!
Damage to the pump set!
▷
Regularly check the condition of the lubricant.
WARNING
Screw plugs subjected to pressure
When opening screw plugs, liquid might spurt out!
▷
Wear safety goggles and protective clothing, if required.
▷
Open the screw plug slowly.
For oil quality, oil quantity and procedure see (
7.3
Drainage/cleaning
WARNING
Fluids and supplies posing a health hazard and/or hot fluids and supplies
Hazard to persons and the environment!
▷
Collect and properly dispose of flushing medium and any residues of the fluid
handled.
▷
Wear safety clothing and a protective mask, if required.
▷
Observe all legal regulations on the disposal of fluids posing a health hazard.
1. Always flush the pump if it has been used for handling noxious, hot or other
hazardous fluids.
Always flush and clean the pump before transporting it to the workshop. Provide
a cleaning record for the pump.
7.4
Dismantling the pump set
DANGER
Insufficient preparation of work on the pump (set)
Risk of personal injury!
▷
Properly shut down the pump set.
▷
Close the shut-off elements in the discharge line.
▷
Drain the pump and release the pump pressure.
▷
Close any auxiliary connections.
▷
Allow the pump set to cool down to ambient temperature.
7 Servicing/Maintenance
WKTR