5 Installation at Site
26 of 52
KSB SuPremE
5.4.3 Direction of rotation
The motors are configured for clockwise and anti-clockwise rotation as standard.
Clockwise rotation
Connecting the motor cables in the phase sequence to U1, V1 and W1 of the
frequency inverter (PumpDrive) results in clockwise rotation (looking at the drive-end
shaft end).
Anti-clockwise rotation
Interchanging two connections results in anti-clockwise rotation.
The parameter settings for the frequency inverter can be altered to reverse the
direction of rotation without changing a connection. See the relevant operating
manual for PumpDrive 2 or PumpDrive R.
5.5 Tightening torques
Conductor glands in the terminal box
DANGER
Damage to insulation of conductors (cores)
Danger from electric shock!
Damage to the motor!
▷
Adjust the tightening torques for the conductor insulation.
▷
Do not exceed the tightening torques.
For cable glands made from metal and plastic for establishing a direct connection to
a drive, and for other glands (e.g. reducers), refer to the following table to apply the
correct tightening torques.
Table 20:
Bolt/screw sizes and tightening torques for the electrical connection
Shaft
centreline
height
Terminal
box/
terminal
box cover
Terminal
board
connections
Terminal
board
fastening
Earth
conductor
connection
Cable gland
(conductors)
[mm]
Number of bolts/screws
8
3
2
1
1
71
Thread
M5
M4
M4
M5
M25
Tightening torque [Nm]
4,5
2
3
6
4
80
Thread
M5
M4
M4
M5
M25
Tightening torque [Nm]
4,5
2
3
6
4
90
Thread
M5
M4
M4
M5
M25
Tightening torque [Nm]
4,5
2
3
6
4
100
Thread
M5
M4
M4
M5
M25
Tightening torque [Nm]
4,5
2
3
6
4
112
Thread
M5
M4
M4
M5
M25
Tightening torque [Nm]
4,5
2
3
6
4
132
Thread
M5
M5
M5
M6
M25
Tightening torque [Nm]
4,5
3
45
10
4
160
Thread
M6
M6
M5
M6
M32
Tightening torque [Nm]
10
5
45
10
6
180
Thread
M6
M6
M6
M6
M32/M40
Tightening torque [Nm]
10
5
10
10
6
200
Thread
M8
M8
M8
M8
M40
Tightening torque [Nm]
23
10
95
23
6
225
Thread
M8
M8
M8
M8
M40
Tightening torque [Nm]
23
10
95
23
6
Summary of Contents for SuPreme Series
Page 1: ...Synchronous Reluctance Motor KSB SuPremE Installation Operating Manual ...
Page 49: ......