7 Servicing/Maintenance
54 of 92
ILN / ILNC / ILNR
5211.8/08-EN
CAUTION
Improper reassembly
Damage to the pump!
▷
Reassemble the pump (set) in accordance with the general rules of sound
engineering practice.
▷
Use original spare parts only.
Sequence
Always reassemble the pump in accordance with the corresponding general assembly
drawing or exploded view. (
Sealing elements
Check O-rings for any damage and replace by new O-rings if required.
Always use new gaskets, making sure that they have the same thickness as the old
ones.
Always fit gaskets of asbestos-free materials or graphite without using lubricants
(e.g. copper grease, graphite paste).
Assembly aids
Avoid the use of assembly adhesives if possible.
Should an assembly adhesive be required after all, use a commercially available
contact adhesive (e.g. Pattex) or sealant (e.g. HYLOMAR or Epple 33).
Only apply adhesive at selected points and in thin layers.
Never use quick-setting adhesives (cyanoacrylate adhesives).
Coat the locating surfaces of the individual components with graphite or similar
before reassembly.
Prior to reassembly, screw back any forcing screws and adjusting screws.
Tightening torques
For reassembly, tighten all screws and bolts as specified in this manual.
(
7.5.2 Assembling the pump set: ILN
7.5.2.1 Installing the bearing assembly
Single-suction version
General assembly drawings per pump size (
Sizes in accordance with general assembly drawing 1:
ü
The individual parts have been placed in a clean and level assembly area.
ü
All dismantled parts have been cleaned and checked for wear.
ü
Any damaged or worn parts have been replaced by original spare parts.
ü
The sealing surfaces have been cleaned.
1. Press deep groove ball bearing 321 and/or rolling element bearing 320 onto
shaft 210 as far as it will go.
2. Fit circlip 932.1.
3. Insert thrower 507 into casing cover 161.
4. Insert pre-assembled shaft 210 into casing cover 161.
5. Fit circlip 932.2.
6. Press bearing cover 360 into casing cover 161.