5 Installation at Site
26 of 92
ILN / ILNC / ILNR
5211.8/08-EN
WARNING
Connecting the pump set prior to installing it on the foundation
Personal injury and damage to property!
▷
Only connect the suction nozzle and discharge nozzle to the piping after the
pump set has been installed on the foundation.
WARNING
Mounting the motor prior to installing the pump on the foundation
Personal injury and damage to property!
▷
Only mount the motor after the pump has been installed on the foundation
and the pump nozzles have been connected to the piping.
CAUTION
Dry running / Ingress of leakage into the motor
Damage to the motor!
▷
Always install the pump set in a vertical position.
Installing the pump set in a vertical position
If the foundation bolts are to be inserted into the holes provided: Insert the
foundation bolts into the corresponding openings.
5.4 Piping
5.4.1 Connecting the piping
DANGER
Impermissible loads acting on the pump nozzles
Danger to life from escaping hot, toxic, corrosive or flammable fluids!
▷
Do not use the pump as an anchorage point for the piping.
▷
Anchor the pipes in close proximity to the pump and connect them properly
without transmitting any stresses or strains.
▷
Observe the permissible forces and moments at the pump nozzles.
▷
Take appropriate measures to compensate for thermal expansion of the piping.
CAUTION
Incorrect earthing during welding work at the piping
Destruction of rolling element bearings (pitting effect)!
▷
Never earth the electric welding equipment on the pump or baseplate.
▷
Prevent current flowing through the rolling element bearings.