1
2
Fig. 9: Filter in the piping
1
Differential pressure gauge
2
Filter
NOTE
Use a filter with laid-in wire mesh (mesh size max. 0.25 mm) made of corrosion-resistant
material.
Use a filter with a filter area three times the cross-section of the piping.
Conical filters have proved suitable.
4. Connect the pump nozzles with the piping.
CAUTION
Aggressive flushing and pickling agents
Damage to the pump!
▷
Match the cleaning operation mode and duration for flushing and pickling
service to the casing and seal materials used.
5.4.3 Permissible forces and moments at the pump nozzles
F
V
F
Vmax
2
F
H
F
Hmax
2
M
tmax
M
t
2
+
+
- 1
Fig. 10: Forces and moments at the pump nozzles
The following condition must be met:
∑
IF
V
I,
∑
IF
H
I, and
∑
IM
t
I are the sums of the absolute values of the respective loads
acting on the nozzles. Neither the load direction nor the load distribution among the
nozzles are taken into account in these sums.
Table 8: Permissible forces and moments at the pump nozzles
Size
Etaseco G
Etaseco S
Etaseco C
F
Vmax
[kN]
F
Hmax
[kN]
M
tmax
[kNm]
F
Vmax
[kN]
F
Hmax
[kN]
M
tmax
[kNm]
F
Vmax
[kN]
F
Hmax
[kN]
M
tmax
[kNm]
32-125.1
2.6
1.8
0.55
3.65
2.59
0.58
4.16
2.95
0.85
32-160.1
2.5
1.7
0.5
3.56
2.51
0.51
4.10
2.87
0.80
32-200.1
2.5
1.7
0.5
3.60
2.43
0.51
4.10
2.78
0.80
32-250.1
2.5
1.7
0.5
--
--
--
4.25
2.96
0.95
32-125
2.6
1.8
0.55
--
--
--
4.16
2.95
0.85
32-160
2.5
1.7
0.5
3.56
2.51
0.51
4.10
2.87
0.80
32-200
2.5
1.7
0.5
3.65
2.43
0.51
4.10
2.78
0.80
32-250
2.5
1.7
0.5
3.73
2.59
0.58
4.25
2.96
0.95
40-125
2.6
1.8
0.6
--
--
--
4.34
3.04
1.26
40-160
2.6
1.8
0.6
3.81
2.67
0.81
4.34
3.04
1.26
5 Installation at Site
22 of 60
Etaseco/Etaseco I
Summary of Contents for Etaseco C
Page 59: ......