4.1 General description
▪
Fully integrated in-line water pump with continuously variable speed control
▪
Non-self-priming in-line pump with integrated permanent magnet motor and
electronic variable speed system
▪
Pump for handling clean, non-aggressive fluids which are not chemically and
mechanically aggressive to the pump materials
4.2 Product information
4.2.1 Product information as per Ecodesign for Energy-Related Products Regulations
2010
▪
Minimum efficiency index: see name plate, key to name plate
▪
The benchmark for the most efficient water pumps is MEI ≥ 0.70.
▪
Year of construction: see name plate, key to name plate
▪
Manufacturer’s name or trade mark, commercial registration number and place
of manufacture: see data sheet or order documentation
▪
Product’s type and size identificator: see name plate, key to name plate
▪
Hydraulic pump efficiency (%) with trimmed impeller: see data sheet
1)
▪
Pump performance curves, including efficiency characteristics: see documented
characteristic curve
▪
The efficiency of a pump with a trimmed impeller is usually lower than that of a
pump with the full impeller diameter.
1)
Trimming of the impeller will adapt the
pump to a fixed duty point, leading to reduced energy consumption. The
minimum efficiency index (MEI) is based on the full impeller diameter.
▪
Operation of this water pump with variable duty points may be more efficient
and economic when controlled, for example, by the use of a variable speed drive
that matches the pump duty to the system.
▪
Information on dismantling, recycling and disposal after decommissioning:
▪
Information on benchmark efficiency or benchmark efficiency graph for
MEI = 0.70 (0.40) for the pump based on the model shown in the Figure are
available at:
http://www.europump.org/efficiencycharts
4.2.2 Product information as per Regulation No. 1907/2006 (REACH)
For information as per chemicals Regulation (EC) No. 1907/2006 (REACH), see
www.ksb.com/ksb-en/About-KSB/Corporate-responsibility/reach/
4.3 Designation
Table 4:
Designation example
Position
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
E
3
0
B
-
H
0
6
5
G
P
S
V
1
1
3
5
0
7
5
O
O
Table 5:
Designation key
Position
Code
Description
1-4
Pump type series/generation
E30B
EtaLine Pro
5
Model
1
There is no trimmed impeller for this type series.