3 Transport/Storage/Disposal
13 of 92
KSB Delta Macro
1983.843/04-EN
3 Transport/Storage/Disposal
3.1 Checking the condition upon delivery
1. On transfer of goods, check each packaging unit for damage.
2. In the event of in-transit damage, assess the exact damage, document it and
notify KSB or the supplying dealer and the insurer about the damage in writing
immediately.
3.2 Transport
DANGER
Pressure booster system tipping over
Risk of injury by falling pressure booster system!
▷
Never suspend the pressure booster system by its power cable.
▷
Observe the applicable local accident prevention regulations.
▷
Observe the information on weights, centre of gravity and fastening points.
▷
Use suitable and permitted transport equipment, e.g. crane, forklift or pallet
truck.
▷
To transport the pressure booster system, suspend it from the lifting tackle as
illustrated.
ü
Transport equipment / lifting equipment suitable for the corresponding weight
has been selected and is on hand.
ü
If the control cabinet and pressure booster system need to be lifted separately
from each other: Disconnect the power cables before lifting the pressure booster
system / control cabinet.
1. Remove the packaging. Remove the caps from the connection openings.
2. Check for any in-transit damage.
3. Transport the pressure booster system to the place of installation.
4. Detach the pressure booster system from the pallet using a suitable tool.
A
A
Fig. 1:
Lifting the pressure booster system off the pallet
5. Undo the bolts (A) between the pressure booster system and the pallet.