5 Installation at Site
26 of 116
CHTRa
5 Installation at Site
5.1 Safety regulations
DANGER
Improper installation in potentially explosive atmospheres
Explosion hazard!
Damage to the pump set!
▷
Comply with the applicable local explosion protection regulations.
▷
Observe the information in the data sheet and on the name plates of pump and
motor.
DANGER
Unprotected floor openings and/or foundations
Danger of death from falling!
▷
Secure the danger zone.
▷
Observe the applicable local occupational safety and accident prevention
regulations.
5.2 Checks to be carried out prior to installation
Place of installation
WARNING
Installation on mounting surface which is unsecured and cannot support the load
Personal injury and damage to property!
▷
Use a concrete of compressive strength class C12/15 which meets the
requirements of exposure class XC1 to EN 206-1.
▷
The mounting surface must be set, flat, and level.
▷
Observe the weights indicated.
DANGER
Insufficient stability of pump set as a result of incorrect dimensioning and
fastening of the baseplate (unless included in KSB's scope of supply)
Risk of pump tipping over!
▷
Prior to commissioning, provide proof that the baseplate is adequately
dimensioned to ensure the pump set’s stability, and proof of compliance with
the maximum permissible vibration level.
▷
Make sure that the vibrations do not exceed the specified limits.
ü
Proper illumination is available at the place of installation.
ü
Suitable alignment devices are available.
ü
In the area of the baseplate grouting and at the side walls of the holes for the
foundation bolts, the foundation has rough surfaces to allow for better bonding.
1. Check the structural requirements.
All structural work required must have been prepared in accordance with the
dimensions stated in the outline drawing/general arrangement drawing.