5 Installation/Dismantling
23 of 44
4STQ
2580.821/04-EN
5.3.5 Installing the double cartridge seal C120/120M1-4STQ
CAUTION
Use of grease or other permanent lubricants
Torque transmission impeded / overheating of and damage to the pump!
▷
Never use grease or other permanent lubricants for fitting the torque-
transmitting elements of a mechanical seal.
▷
Use soft soap to reduce any friction caused during assembly.
▷
Never coat the mechanical seal faces with grease or oil.
ü
The relevant documentation for installing the mechanical seal is observed.
(
ü
The back pull-out unit has been removed from the pump casing and safely
positioned and secured in a horizontal position.
ü
The original 4STQ cartridge seal is fully assembled and undamaged.
1. Apply a suitable lubricant to the O-rings. Ensure that no permanent lubricant
comes into contact with the O-rings, in order to guarantee reliable torque
transmission.
2. Insert O-rings 412.54 and 412.55 in discharge cover 163. Ensure that no
permanent lubricant is used.
3. Fit O-ring 412.59 on the shoulder of shaft seal housing 441.
901
Fig. 11:
Illustration showing hexagon head bolt
4. Completely remove the hexagon head bolts 901 (x 3) that make up the transport
lock and store them.
5. Apply a coat of a suitable grease to shaft 210 in the area of the mechanical seal
and the impeller hub.
6. Align the groove in shaft sleeve 523 with the groove in shaft 210.
7. Carefully slide the entire cartridge mechanical seal 4STQ onto the shaft until seal
cover 471 abuts discharge cover 163. Apply the axial force required for insertion
into the discharge cover via the seal cover only. Ensure that primary ring 472.52
and mating ring 475.52 are not damaged. A tube with an inside diameter larger
than 170 mm and outside diameter smaller than 190 mm can be used to press
the stationary seal cover into the discharge cover of the pump.
8. Fit circlip 932.53 in the groove of discharge cover 163. Make sure it is correctly
seated.
Summary of Contents for 4STQ Series
Page 1: ...KSB Mechanical Seal 4STQ Installation Operating Manual...
Page 43: ......