4
Technical data
4.1
Consumables
36
KWT 1600
Original Operating Instructions 150000169_04_en
Minimum requirements for the tractor
Power requirement
60 kW (80 HP)
PTO speed
max. 540 rpm
Min. operating pressure of hydraulic system
180 bar
Max. operating pressure of hydraulic system
200 bar
Voltage lighting
12 V, 7-pin
Delivery capacity of the hydraulic pump
20 L/min
Removable hydraulic oil quantity
at least 10 L
Lower link, fixable height and sides
Optional
Required hydraulic connections
Single-acting hydraulic connection
1x
Double-acting hydraulic connection
1x
Machine equipment
Lower link hitch
Cat. II
Number of rotors
14
Number of tine arms per rotor
6
Universal shaft
Wide angle
Spreading angle setting
13°-19°
Safety chain
at least 44 kN (10,000 Ibf)
Airborne noise emission
Emissions value (sound pressure level)
68.8 dB (A)
Measurement device
Bruel & Kjaer, Type 2236
Accuracy class
2
Measurement uncertainty (according to DIN EN ISO 11201)
4 dB
Ambient temperature
Temperature range for machine operation
-5 to +45 °C
4.1
Consumables
NOTICE
Complying with change intervals for biooils
To ensure high life expectancy of the machine, it is absolutely necessary to comply with
change intervals for biooils due to the ageing of the oils.
NOTICE
Machine damage due to mixing of oil
If oils, which have different specifications, are mixed with each other, the machine may be
damaged.
Never mix oils, which have different specifications, with each other.
Contact your KRONE service partner before using an oil with a different specification after
changing the oil.