Malfunction, cause and remedy
17
Faults of the electrics/electronics
17.5
Comprima V 180
Original Operating Instructions 150001053_00_en
201
The following key functions can be selected:
Symbol
Designation
Explanation
Acknowledging the error
message
If the fault occurs again, the error message
will appear again.
Delete error message
The error message will no longer be dis-
played until the operating terminal is next
started.
17.5.1.1
Possible error types (FMI)
There are different types of errors which are shown under the term FMI (Failure Mode
Identification) with an appropriate code.
FMI
Meaning
0
The upper limit value was greatly exceeded.
1
The lower limit value was far below the required one.
2
The data is not permitted.
3
There is an overvoltage or a short circuit to supply voltage.
4
There is an undervoltage or a short circuit to ground.
5
A cable is broken or amperage is too low.
6
There is a short circuit to ground or amperage is too low.
7
The mechanics do not respond or the expected result was not achieved.
8
The frequency is not permitted.
9
There is an abnormal update rate.
10
There is an abnormal rate of change.
11
The error cause is unknown.
12
There is an internal error.
13
The values of the calibration are outside the value range.
14
Particular instructions are required.
15
The upper limit value has been reached.
16
The upper limit value has been exceeded.
17
The lower limit value has been reached.
18
The lower limit value has not been reached.
19
There is a CAN communication failure.
20
The data deviates upwards.
21
The data deviates downwards.
31
The condition has been fulfilled.
17.5.2
Overview of fuses
The circuit board with the fuses is located on the right side of the machine behind the side hood.
As indicated on the circuit diagram (
), the following fuses are on the circuit
board: