Malfunction, cause and remedy
17
Malfunctions on the central chain lubrication system
17.4
Comprima V 180
Original Operating Instructions 150001053_00_en
199
Possible cause
Remedy
The wrapping material brake
has not been correctly set.
Adjust the wrapping material brake,
17.4
Malfunctions on the central chain lubrication system
Malfunction:
The oil consumption is too low.
Possible cause
Remedy
The nozzles of the central
chain lubrication system are
soiled so that the pump pres-
sure is too low.
Clean the dosing units of the central chain lubrication
system,
.
Clean the pump,
The pressure is too low, as
the pump is not pressed in for
the complete stroke.
.
Have the pump removed and cleaned or replaced by a
KRONE service partner.
The oil is too thick.
Use recommended oil,
The central chain lubrication
system is contaminated.
Clean the entire central chain lubrication system.
Malfunction:
The oil consumption is too high.
Possible cause
Remedy
The main tube is torn.
Have the main tube repaired or replaced changed by a
KRONE service partner.
The oil is too thin.
Use recommended oil,
Reduce the set oil quantity.
Malfunction:
The machine is dry.
Possible cause
Remedy
There is no pressure. The
pump is not functioning.
Have the pump removed and cleaned or replaced by a
KRONE service partner.
There is no pressure. The
main tube is torn.
Have the main tube repaired or replaced changed by a
KRONE service partner.
There is no pressure. The
system has no oil.
Bleed the central chain lubrication system,
The system is blocked by de-
posits.
Clean the entire central chain lubrication system.
The system is blocked, as the
main tube is jammed.
Have the main tube repaired or replaced changed by a
KRONE service partner.
Malfunction:
The pump is not pressed for the full stroke.
Possible cause
Remedy
The oil is too thick.
Use recommended oil,
The dosing units are blocked.
.