![Krone Comprima F 125 XC-1 Operating Instructions Manual Download Page 258](http://html1.mh-extra.com/html/krone/comprima-f-125-xc-1/comprima-f-125-xc-1_operating-instructions-manual_2004803258.webp)
3
KRONE ISOBUS terminal (CCI 200, DELTA terminal)
3.1
ISOBUS Shortcut Button (ISB)
14
Comprima F 125 - 1, Comprima F 125 XC - 1, Comprima F 155 - 1, Comprima F 155 XC - 1, Comprima V 150 - 1,
Comprima V 150 XC - 1, Comprima V 180 - 1, Comprima V 180 XC - 1, Comprima V 210 XC - 1
Comfort 1.0_en
3.1
ISOBUS Shortcut Button (ISB)
WARNING
The ISOBUS Shortcut Button is not an EMERGENCY STOP switch. If the ISOBUS
Shortcut Button is confused with the EMERGENCY STOP switch, there is danger to life.
When actuating the ISOBUS Shortcut Button, activated machine functions are deactivated.
Process oriented procedures perform to the end. Therefore machine parts can continue to run
after actuating the ISOBUS Shortcut Button. This may lead to injuries.
The ISOBUS Shortcut Button does in no case intervene in the tractor functions, i.e. neither
the universal shaft function nor the hydraulic function is affected. Therefore, the machine can
continue to run after actuating the ISOBUS Shortcut Button. This may lead to injuries.
Never use the ISOBUS Shortcut Button as an EMERGENCY STOP switch.
When the ISOBUS Shortcut Button (1), designed as a pushbutton, is pressed on the terminal, a
stop command is sent to the ISOBUS. This command is evaluated by the connected ISOBUS
machine to deactivate activated machine functions. Process-oriented sequences run through to
the end. If the ISOBUS Shortcut Button is pressed, the display will indicate a corresponding
error message:
1
EQ000-070
Actuating ISOBUS Shortcut Button
Press ISOBUS Shortcut Button (1).
Æ
The message above appears in the display.
The job computer blocks the following functions on machine side:
•
All machine-sided hydraulic functions
•
The electronic tying unit