Maintenance - General information
16
Checking the fire extinguisher
16.8
BiG Pack 870 HDP XC
Original Operating Instructions 150000760_00_en
249
16.8
Checking the fire extinguisher
1
BPG000-034
ü
The machine is shut down and safeguarded,
.
Ensure that that fire extinguisher (1) is mounted on the machine.
Ensure that the access and view on the fire extinguisher (1) are not obstructed.
Ensure that the fire extinguisher (1) is filled by weighing it.
Ensure by a visual inspection that the seal on the erase head and the securtiy seal are
neither defective nor missing.
Check visually if the operating instructions on the type plate of the fire extinguisher (1) are
readable and show to the outside.
Check if the fire extinguisher is affected by apparent material damage, corrosion, leakage or
a clogged hose and/or nozzle.
Ensure that the pressure gauge is in the green operating range.