Terminal – machine functions [Medium 1.0/Comfort 1.0]
12.23 Setting target baling force (automatic mode)
138
BiG Pack 870 HDP XC
Original Operating Instructions 150000760_00_en
20
4 cm
38 %
94 /
240
cm
2 /
4
1
2
EQG000-030
Value (1) and the bar display = actual bale channel flap pressure
Value (2) and the red mark on the bar display = set target bale channel flap pressure
Setting the target bale channel flap pressure
ü
Manual mode has been selected,
.
Change value,
.
12.23
Setting target baling force (automatic mode)
In Automatic mode, the pressure is automatically set based on the measured plunger force. The
pressure indication on the display may fluctuate considerably. The control functions only when
the packer is supplying forage to the piston. The baling force is displayed as a precentage.
20
4 cm
108 bar
94 /
240
cm
2 /
4
2
1
EQG000-031
Value (1) and the bar displays on right/left = actual baling force as %.
Value (2) and the red marks on the bar displays = target baling force as %.
Setting the target force of pressure
ü
Automatic mode has been selected,
Change value,
.
12.24
Setting target bale length
INFORMATION
The target bale length (2) can be changed steplessly at any time. It is not recommended to
switch over the target bale length at the end of the bale, as the knotter could actuate too late.