Machine description
4
Description of functions of electric knotter monitoring
4.14
BiG Pack 1290 HDP XC
Original Operating Instructions 150000752_01_en
51
Possible malfunctions when the twine motion indicators (1) remain at the top:
•
Twine has wrapped around the billhook.
•
The knotter needle has missed the upper twine strand (twine is not cut).
•
The knot has been left hanging on the billhook (after tying is completed one twine indicator
(1) stays down longer than the other ones).
Possible malfunctions when the twine motion indicators (1) remains at the bottom:
•
The twine tension is too low.
•
The upper twine strand is torn.
•
The billhook has not tied a knot.
4.14
Description of functions of electric knotter monitoring
For “Comfort 1.0” version
BP000-070
The machine is equipped with an electrical knotter monitoring. In this process, each knotter is
monitored individually by a sensor (1). If an error has occurred on the knotter, an error message
will appear on the display of the terminal,
.
The knotters are numbered from 1 to 6 in direction of travel from left to right.
4.15
Description of knotter gearbox functions
BP000-071 / EQ000-072
Knotter gearbox in idle position
The knotter gearbox is in idle position if the trigger roller (1) is located in the recess of the cam
disc (2) of the knotter gearbox.