Maintenance - General information
16
Drain condensation water from the compressed air tank
16.8
BiG Pack 1270
Original Operating Instructions 150000747_02_en
211
16.8
Drain condensation water from the compressed air tank
WARNING
Risk of injury from corroded or damaged compressed air reservoirs
Damaged or corroded compressed air reservoirs may burst and cause serious injuries.
Observe the inspection intervals according to maintenance table,
.
Have damaged or corroded compressed air reservoirs replaced immediately by a
specialist workshop.
NOTICE
Damage to compressed air reservoir caused by water in the compressor unit
Water in the compressor unit leads to corrosion which damages the compressed air reservoir.
Check and clean drain valve according to maintenance table,
.
Immediately replace a defective drain valve.
DVG000-014
Compressed air reservoir for “compressed air
brake” version
Compressed air reservoirs for knotter cleaning
Shut down and safeguard the machine,
.
WARNING! Risk of eye injury due to spurting condensation water! Wear suitable
protective goggles.
ü
A suitable container is available for escaping condensation water.
Open the drain valve (2).
Æ
Allow compressed air and condensation water to escape out of the compressed-air tank (1).
Visually inspect the drain valve (2) to ensure that it is not defective or soiled.
Æ
If the drain valve (2) is defective and is no longer sealed, immediately have the drain
valve (2) replaced by a KRONE service partner.
Æ
If the drain valve (2) is soiled, clean the drain valve (2).