8
Start-up
8.9
Connecting the KRONE ISOBUS terminal (CCI 1200)
92
BiG Pack 1270 XC
Original Operating Instructions 150000748_01_en
Tractors without ISOBUS system
EQ001-144
ü
The machine is shut down and safeguarded,
.
ü
The accessories kit B290 “KRONE tractor retrofitting” is mounted.
Connection terminal to tractor
Connect the 8-pin plug (2) of the cable (3) to the 8-pin socket (1) (CAN1-IN) of the terminal.
Connect the 9-pin plug (4) of the cable (3) to the 9-pin socket (5) (In-cab).
Connection tractor to machine
INFORMATION
The cable (8) can be ordered by quoting the order number 20 086 886 *.
Connect the 9-pole plug (7) of the cable (8) to the 9-pole ISOBUS socket (6) of the tractor.
Connect the 11-pole plug (9) of the cable (8) to the 11-pole socket (10) of the machine.
8.9
Connecting the KRONE ISOBUS terminal (CCI 1200)
NOTICE
Short circuit caused by impurities and moisture in the plug connection
The machine may be damaged by a short circuit.
Make sure that the plugs and sockets are clean and dry.