![Krone Big Pack 1270 XC Original Operating Instructions Download Page 75](http://html1.mh-extra.com/html/krone/big-pack-1270-xc/big-pack-1270-xc_original-operating-instructions_2004793075.webp)
Initial operation
7
Adjusting universal shaft (for the version with “PreChop”)
7.5
BiG Pack 1270 XC
Original Operating Instructions 150000748_01_en
75
Dismounting outer guard tube
1
2
5
3
4
6
1
7
BP000-394
Use a screwdriver (3) to pull the collar (1) over the locks (4) of the guard funnel (2).
Screw out the 3 screws (5).
Turn the collar (1) until you can feel a stop (6) and push back the outer guard tube (7).
Dismounting inner guard tube
1
2
3
4
BP000-395
Loosen the inner guard tube (1) from the slide ring (3) by lightly tapping the cap (2) and
push it back.
Dismount the seal (4).