Terminal – menus [Medium Plus/Comfort Plus Electronics]
8
Menu 1 "Knotter"
8.7
Supplement to Operating Instructions 150000774_00 _en
BiG Pack 870 HDP, BiG Pack 870 HDP XC
51
.
Display area
Item
Designation
Explanation
(1)
Blowing time
•
In seconds.
•
Adjustable value range: 1 - 8 s
Info:
To prevent an excessive pressure drop on
the pressure vessel, it is recommended first to
shorten the blowing interval,
Change value,
8.7.6
Menu 1-9 "Calibrate MultiBale"
In this menu the sensor for locking the MultiBale can be calibrated. Following repair work, a
calibration may be required due to high operational demands or settling of the components, if
the centre bar is higher or lower than the outer bars.
1-9
4,9V 0,9V 1,1V
EQ001-005 / EQ001-082
ü
Menu 1 "Knotter" has been selected,
.
To open the menu, press
.
Æ
The display shows the "Calibrate MultiBale" menu.
.
ü
The machine is shut down and safeguarded,
.
ü
The compressor unit has been filled.
Moving lock to "MultiBale" position
1-9
4,9V 4,9V 1,1V
1
2
EQ001-082 / BP000-389
Press and hold down
until the centre bar and the left bar are the same height.