IV - 34
Comfort Control Unit
4.9 Alarm Messages
4.9.1 General alarms
No
.
Screen Description
Possible
cause
Remedy
A1
Plug-in fuse in job
computer defective
Short circuit at electrical outputs
+12V2FU_L
Check the connection
for short circuit and
replace fuse
A2
Fuse in job
computer defective
Short circuit at electrical outputs
+12V3FU_L
Check the connection
for short circuit. The
fuse resets itself after
the unit has cooled
down
A03
CAN error
The CAN bus was interrupted
between the control unit and the
machine. -> loose contact in the
connection to the display
Check the display line
A14
Undervoltage
- Tractor battery defective
- Tractor dynamo too weak
- 12-V power supply too weak on the
tractor side or not correctly connected
with the battery
Connect the KRONE
connection cable to
the tractor battery
A15
Overvoltage
Tractor dynamo defective
Check dynamo