BIC · Edition 09.22
EN-2
2 CHeCKInG tHe UsAGe
Burner for heating industrial thermoprocessing equip-
ment. Burners BIC or BICA can be used in conjunction
with the ceramic tube set TSC in industrial furnaces or
firing systems with brick lining or ceramic fibre lining. No
burner block is necessary. For natural gas, town gas
and LPG. Other types of gas on request. This function
is only guaranteed when used within the specified
limits – see also page 15 (10 Technical data). Any
other use is considered as non-compliant.
2.1 type label
Construction stage, rated capacity Q
max
, gas type and
diameter of gas measuring orifice (as of construction
stage E) – see type label.
Elster GmbH
Osnabrück, Made in Germany
BIC 80HB-0/35-(16)F
84032010
P 90; 105; 120 kW
Ø 12 mm
.3322
2.2 type code
BIC
Burner for gas, with connection for
ceramic tube
BICA
Burner for gas, with aluminium housing
and connection for ceramic tube
BICW
Burner for gas, with ceramic fibre insula-
tion (RCF)
50-140
Burner size
R
Cold air
H
Hot air/high furnace temperature
L
For high excess air and a large ignition
range
M
For menox low NOx operation
B
Natural gas
D
Coke oven gas, town gas
G
Propane, propane/butane, butane
M
Propane, propane/butane, butane (with
mixer)
L
Low calorific value gas
F
Biogas
L
integrated pilot
R
Reduced capacity
-X
X mm length of steel tube as of furnace
flange (L1)
/X
X mm distance from furnace flange to
front edge of burner head (L2)
-(X)
Burner head identifier
-(Xe)
Heat-resistant version
A-Z
Construction stage
H
High temperature version
2.3 Part designations
1
4
5
3
6
7
2
8
9
1
Burner insert
2
Type label
3
Gas housing gasket
4
Air housing
5
Mounting flange for TSC (for BIC(A)..-0)
6
Mounting gasket (not included in the delivery)
7
Burner extension with clamping ring (for
BIC(A)..-100, -200 …)
8
Clamping ring
9
Operating instructions – for more documents
and calculation tools, see www.adlatus.org
2.4 Burner head
➔
Check letter marking and identification marks on
the burner head using the information provided
on the type label.
2.5 Ceramic tube
type label
Length and diameter – see type label.
D-49018 Osnabrück Germany
TSC 65A048-300/35-
74924401
SI-1500
2.6 type code
tsC
Ceramic tube set
50-140
Burner size
A
Cylindrical shape
B
Tapered shape
020–180
Outlet diameter [mm]
200–300
Length [mm]
/35–, /135-
Distance from furnace flange
to front edge of burner baffle plate [mm]
si
Silicon-infiltrated SiC
1500
Up to 1500°C