INSTALLATION
2
9
TIDALFLUX 2300 F
www.krohne.com
06/2013 - 4002489402 - QS TIDALFLUX 2300 R02 en
2.8.8 Mounting position
2.9 Mounting
2.9.1 Mounting grounding rings
CAUTION!
Only install the flow sensor in the shown position to keep the electrodes under water. Limit the
rotation to
±
2
°
to maintain the accuracy.
Figure 2-13: Mounting position
CAUTION!
In order to get a reliable height measurement it is absolutely necessary
absolutely necessary
absolutely necessary
absolutely necessary that the inner side of the
connecting pipeline is electrically conductive and connected to ground. If not, tailor-made
grounding rings with a cylindrical part can be delivered. Please contact your local agency in case
of doubt.
Figure 2-14: Grounding with grounding rings
1
Existing pipeline
2
Grounding rings, custom made to inner diameter of pipeline
3
TIDALFLUX
4
Insert the cylindrical part of the grounding ring into the pipeline. Use an appropiate gasket between the grounding ring
and the flange.
INFORMATION!
Sizes of the grounding rings are diameter dependent and available on request.