background image

Electromagnetic flow sensor in sandwich version

OPTIFLUX 1000

OPTIFLUX 1000

OPTIFLUX 1000

OPTIFLUX 1000

Quick Start 

Quick Start 

Quick Start 

Quick Start 

© KROHNE 10/2011 - 7309832300 - QS OPTIFLUX 1000 R03 en

The documentation is only complete when used in combination with the relevant 
documentation for the signal converter.

Summary of Contents for OPTIFLUX 1000

Page 1: ...00 OPTIFLUX 1000 OPTIFLUX 1000 OPTIFLUX 1000 Quick Start Quick Start Quick Start Quick Start KROHNE 10 2011 7309832300 QS OPTIFLUX 1000 R03 en The documentation is only complete when used in combinati...

Page 2: ...g position 7 2 6 3 Flange deviation 8 2 6 4 T section 8 2 6 5 Vibration 8 2 6 6 Magnetic field 9 2 6 7 Bends 9 2 6 8 Open discharge 10 2 6 9 Control valve 10 2 6 10 Air venting 10 2 6 11 Pump 11 2 6 1...

Page 3: ...ons can result in damage to the device or to parts of the operator s plant INFORMATION These instructions contain important information for the handling of the device CAUTION Installation assembly sta...

Page 4: ...office of the manufacturer INFORMATION The device will arrive in two cartons One carton contains the converter and one carton contains the sensor Figure 2 1 Scope of delivery 1 Ordered flowmeter 2 Pr...

Page 5: ...on electrical connection to the measuring sensor via field current and signal cable 2 3 Nameplates 1 Remote version 2 Compact version with IFC 300 signal converter 3 Compact version with IFC 100 0 sig...

Page 6: ...1 7309832300 QS OPTIFLUX 1000 R03 en 2 4 Storage Store the device in a dry and dust free location Avoid lasting direct exposure to the sun Store the device in its original packing Storage temperature...

Page 7: ...UX 1000 www krohne com 10 2011 7309832300 QS OPTIFLUX 1000 R03 en 2 6 Installation conditions 2 6 1 Inlet and outlet 2 6 2 Mounting position Figure 2 3 Recommended inlet and outlet 1 5 DN 2 2 DN Figur...

Page 8: ...OPTIFLUX 1000 R03 en 2 6 3 Flange deviation 2 6 4 T section 2 6 5 Vibration CAUTION Max permissible deviation of pipe flange faces Lmax Lmin 0 5 mm 0 02 Figure 2 5 Flange deviation 1 Lmax 2 Lmin Figur...

Page 9: ...TIFLUX 1000 www krohne com 10 2011 7309832300 QS OPTIFLUX 1000 R03 en 2 6 6 Magnetic field 2 6 7 Bends Figure 2 8 Avoid magnetic fields Figure 2 9 Installation in bending pipes Figure 2 10 Installatio...

Page 10: ...2011 7309832300 QS OPTIFLUX 1000 R03 en 2 6 8 Open discharge 2 6 9 Control valve 2 6 10 Air venting Figure 2 11 Installation before an open discharge Figure 2 12 Installation before control valve Figu...

Page 11: ...ures Figure 2 14 Installation after pump CAUTION Protect the device from direct sunlight Temperature range Process C Ambient C Process F Ambient F min max min max min max min max Separate flow sensor...

Page 12: ...ure rating bar Max torque Nm Flange size Pressure rating DN10 DN15 PN 16 40 16 16 DN15 DN15 PN 16 40 16 16 DN25 DN25 PN 16 40 16 16 DN40 DN40 PN 16 40 16 25 DN50 DN50 PN 16 40 16 45 DN80 DN80 PN 16 40...

Page 13: ...ational health and safety regulations Any work done on the electrical components of the measuring device may only be carried out by properly trained specialists INFORMATION Look at the device nameplat...

Page 14: ...n 3 3 Virtual reference for IFC 300 C W and F version Possible if DN10 Electrical conductivity 200 S cm Electrode cable max 50 m 164 ft type DS 3 4 Connection diagrams Figure 3 3 Virtual reference INF...

Page 15: ...U is generated U v k B D U v k B D U v k B D U v k B D in which v mean flow velocity k factor correcting for geometry B magnetic field strength D inner diameter of flow meter The signal voltage U is...

Page 16: ...h IFC 100 0 IFC 100 0 IFC 100 0 IFC 100 0 a 82 mm 3 2 b 161 mm 6 3 c 257 mm 10 1 1 Total height H a Compact version with Compact version with Compact version with Compact version with IFC 100 45 IFC 1...

Page 17: ...40 150 180 130 5 7 100 16 200 207 156 10 5 150 16 200 271 219 15 0 Nominal size Dimensions inches Approx weight lb ASME PN psi L H W 3 8 580 2 68 5 39 1 85 3 7 580 2 68 5 39 1 85 3 7 1 580 2 13 5 79 2...

Page 18: ...5 NOTES 18 OPTIFLUX 1000 www krohne com 10 2011 7309832300 QS OPTIFLUX 1000 R03 en...

Page 19: ...NOTES 5 19 OPTIFLUX 1000 www krohne com 10 2011 7309832300 QS OPTIFLUX 1000 R03 en...

Page 20: ...s products Measuring systems for the oil and gas industry Measuring systems for sea going tankers Head Office KROHNE Messtechnik GmbH Ludwig Krohne Str 5 D 47058 Duisburg Germany Tel 49 0 203 301 0 Fa...

Reviews: