DEVICE DESCRIPTION
2
13
OPTIBAR 5060
www.krohne.com
04/2021 - 4003591803 - AD OPTIBAR 5060 Exia R03 en
2.7 Electrical data
2.7.1 With electronics Z (4…20 mA), H (4…20 mA/HART
®
), A (4…20 mA/HART
®
with SIL
qualification)
OPTIBAR * 5060 VGK5/6/D*A/W/V C/U/0/H/T with integrated electronics Z (4…20 mA),
H (4…20 mA/HART
®
) or A (4…20 mA/HART
®
with SIL qualification), version with single
chamber housing A, K, V or 8
Supply and signal circuit:
(Terminals 1[+], 2[-] in the "Ex-i"
electronics compartment or connector)
In protection type intrinsic safety Ex ia IIC/IIB
Only for connection to a certified, intrinsically safe circuit
Maximum values
•
U
i
: 30 V
•
I
i
: 131 mA
•
P
i
: 983 mW
The effective inner capacitance C
i
is negligibly small.
In the version with permanently mounted connection cable,
C
i wire/wire
= 150 pF/m and
C
i wire/shield
= 270 pF/m must be taken into account.
The effective inner inductance L
i
is L
i
5
H. In the version
with permanently mounted connection cable, L
i
= 0.62
H/m
must be taken into account additionally.
Table 2-7: Electrical data for OPTIBAR * 5060 with integrated electronics Z, H or A, version with single chamber housing
A, K, V or 8
OPTIBAR * 5060 VGK5/6/D*A/W/V C/U/0/H/T with integrated electronics Z (4…20 mA),
H (4…20 mA/HART
®
) or A (4…20 mA/HART
®
with SIL qualification), version with double
chamber housing D, W or R
Supply and signal circuit:
(Terminals 1[+], 2[-] in "Ex-i" terminal
compartment)
In protection type intrinsic safety Ex ia IIC/IIB
Only for connection to a certified, intrinsically safe circuit
Maximum values
•
U
i
: 30 V
•
I
i
: 131 mA
•
P
i
: 983 mW
The effective inner capacitance C
i
is negligibly small.
In the version with permanently mounted connection cable,
C
i wire/wire
= 150 pF/m and
C
i wire/shield
= 270 pF/m must be taken into account.
The effective inner inductance L
i
is L
i
10
H. In the version
with permanently mounted connection cable, L
i
= 0.62
H/m
must be taken into account additionally.
Table 2-8: Electrical data for OPTIBAR * 5060 with integrated electronics Z, H or A, version with double chamber
housing D, W or R