![Kratki LEO Series Installation And Operating Instructions Manual Download Page 11](http://html1.mh-extra.com/html/kratki/leo-series/leo-series_installation-and-operating-instructions-manual_2002584011.webp)
INSTRUKCJ
A MONTAŻU I OBSŁUGI –
SERIA LEO wersja 1.0
11
✓
Do not place flammable materials near the fireplace.
✓
It is forbidden to place flammable materials in the combustion chamber.
✓
If you feel a gas leak, do not start the device. Stop the gas supply as soon as
possible, ventilate the room in which the fireplace is located and contact a
service technician.
✓
Broken glass should be replaced immediately. Operation of the appliance with
broken or removed glass is strictly prohibited.
✓
In case of improper functioning of the device, shut off the gas supply and contact
a service technician.
PLEASE NOTE !!!
During operation, the device heats up and it is essential to avoid touching any
surface of the device in normal working conditions, including the windscreen,
side windows, front and side surfaces (called working surfaces) of the body that
may be outside the device's body. In the case of installation of the device in
places where contact with the device may be particularly vulnerable, ie infirm
persons, children or other persons requiring special attention, it is necessary to
protect the device in a way that prevents contact with the working device
mentioned above.
Installation of the appliance
The fireplace is equipped with elements protecting against uncontrolled outflow of gas
from the main burner. Before connecting the device, read all connection diagrams in
the current chapter. The gas cartridge is adapted to connect a special concentric
system that allows simultaneous supply of the fireplace in the air and flue gas
discharge outside the building. In order to ensure correct operation of the device, the
assembly of the fireplace can only be carried out by a person with appropriate
permissions. Before allowing the gas cartridge for use, the installer should:
✓
Carry out leak tests for gas connections made.
✓
Check the correct connection of individual system components.
✓
Check the correct connection of the chimney insert.
✓
Make a trial firing in the cartridge.
✓
Check the correct operation of all system components and system security.