Kramer Electronics Ltd.
UHD Matrix Switcher
– Operating VS-88UHD via Front Panel Buttons
23
Storing and Recalling a Setup
The number of setups that the
UHD Matrix Switcher
is the sum of the inputs and outputs of
the device. For example,
VS-66UHD
,
VS-84UHD
and
VS-48UHD
can store/recall up to 12
setups, while
VS-88UHD
stores/recalls up to 16 setups.
VS-66UHD
,
VS-84UHD
and
VS-48UHD
can store/recall up to 16 setups via the protocol
Each setup includes the video and audio current switching state, the EDID, the ARC/audio
mode, and the switch mode and speed.
In Store-Recall mode, OUT 1 corresponds to setup 1, IN 1 corresponds to setup 9, and so on.
Figure 20: VS-88UHD 8x8 UHD Matrix Switcher Front Panel
To store a setup:
1. Press
STO
.
The
STO
button illuminates.
2. Press an
IN
or an
OUT
button (from 1 to 8).
For example, when pressing IN 5, the current device state is stored to setup 13.
3. Press
STO
.
The current device state is stored to setup 13 and the STO button no longer illuminates.
To recall a setup:
1. Press
RCL
.
The
RCL
button illuminates.
2. Press an
IN
or
OUT
button to recall the setup stored in that IN/OUT.
The selected button flashes.
If a setup is stored in the selected setup button, the corresponding 7-segment display
LED flashes. If nothing is stored the 7-segment LED is on.
3. Press
RCL
.
The recalled setup is applied and the RCL button no longer illuminates.
Press
RCL
within 15 seconds to apply settings. Otherwise, action times out.