Setting Switching Mode
VP-440X
enables configuring for automatic switching of the input source upon signal loss or
when a source is plugged in.
To set the switching mode:
1. On the front panel press
MENU
. The menu appears.
2. Click
Advanced
and select
Auto Switching
.
3. Select the switching mode according to the information in the following table:
Menu Item
Function
Off
For manual switching.
Scan From HDMI
Scans for a valid input, starting with HDMI 1, when no signal is found on
the selected input.
Scan From PC
Scans for a valid input, starting with PC, when no signal is found on the
selected input.
Last Connected
Automatically switches to the last connected input and reverts to the
previously selected input after that input is lost.
Switching mode is defined.
Setting Ethernet Parameters
VP-440X
enables defining the Ethernet parameters via the MENU front panel buttons.
To set the Ethernet parameters:
1. On the front panel press
MENU
. The menu appears.
2. Click
Advanced
and define the Ethernet parameters according to the information in the
following table:
Menu Item
Function
IP Mode
Select Static IP (default) or DHCP.
Static IP Address
Enter to change the IP address.
Subnet Mask
Enter to change the subnet mask.
Default Gateway
Enter to change the default gateway.
TCP Port
Enter TCP port # (5000, by default).
UDP Port
Enter UDP port # (50000, by default).
IP
View the current IP address.
MAC ADDRESS
View the MAC address.
Network parameters are defined.