40
MV-6 - Kramer Protocol 3000 Syntax
CR
= Carriage return (ASCII 13 = 0x0D)
LF
= Line feed (ASCII 10 = 0x0A)
SP
= Space (ASCII 32 = 0x20)
10.3
Command Terms
Command
A sequence of ASCII letters ('A'-'Z', 'a'-'z' and '-').
Command and parameters must be separated by at least one space.
Parameters
A sequence of alphameric ASCII characters ('0'-'9','A'-'Z','a'-'z' and some
special characters for specific commands). Parameters are separated by
commas.
Message string
Every command entered as part of a message string begins with a
message
starting character
and ends with a
message closing character
.
Note
: A string can contain more than one command. Multiple commands are
separated by a pipe ('|') character.
Message starting character
'#' - For host command/query
'~' - For machine response or machine command performed by keystroke
operation on the front panel or IR remote controller.
Device address
(Optional when directly connected to the device)
K-Net Device ID or MACHINE NUMBER followed by '@'
(ex. #02@CR LF )
Query sign
'?' follows some commands to define a query request.
All outputs sign
'*' defines all outputs.
Summary of Contents for MV-6
Page 1: ...KRAMER ELECTRONICS LTD USER MANUAL MODEL MV 6 3G HD SDI Multiviewer P N 2900 000737 Rev 11...
Page 2: ......
Page 46: ...42 MV 6 Kramer Protocol 3000 Syntax 10 7 Maximum String Length 64 characters...
Page 73: ...MV 6 Parameters 69 12 8 Font Size Number Value 0 Small 1 Medium 2 Large...
Page 74: ......