Kramer Electronics Ltd.
FC-7P
– Mounting FC-7P
8
Mounting FC-7P
This section provides instructions for rack mounting
FC-7P
. Before installing in a rack, verify
that the environment is within the recommended range:
•
Operation temperature
– 0
to 40
C (32 to 104
F).
•
Storage temperature
– -40
to +70
C (-40 to +158
F).
•
Humidity
– 10% to 90%, RHL non-condensing.
•
FC-7P
must be placed upright in the correct horizontal position.
Caution:
•
Always mount
FC-7P
in a rack before connecting any cables or power.
Warning:
•
Ensure that the environment (e.g., maximum ambient temperature & air flow) is
compatible for the device.
•
Avoid uneven mechanical loading.
•
Appropriate consideration of equipment nameplate ratings should be used for avoiding
overloading of the circuits.
•
Reliable earthing of rack-mounted equipment should be maintained.
•
Maximum mounting height for the device is 2 meters.
To mount the FC-7P on a rack
Mount the unit in a rack using the recommended rack adapter
(see
www.kramerav.com/product/FC-7P
To mount the FC-7P on a table or shelf
•
Attach the rubber feet and place the unit on a flat surface.
•
Fasten a bracket on each side of the unit and attach it to a flat
surface.
For more information go to
www.kramerav.com/downloads/FC-7P