background image

 

 

 

K R A ME R  E LE CT R O N IC S  L T D .  

USER MANUAL

 

 

MODEL: 

FC-340 

SDI Scaler/Embedder/Scan 
Converter

 

 

 

 

P/N: 2900-000768 Rev 5 

Summary of Contents for FC-340

Page 1: ...KRAMER ELECTRONICS LTD USER MANUAL MODEL FC 340 SDI Scaler Embedder Scan Converter P N 2900 000768 Rev 5...

Page 2: ......

Page 3: ...ault Configuration 16 7 4 Locking and Unlocking the Front Panel 17 7 5 Updating the Firmware Using the K Upload Software 17 8 Technical Specifications 18 9 Default Parameters 19 9 1 Default Communicat...

Page 4: ...roups that are clearly defined by function GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Routers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeate...

Page 5: ...ality due to poor matching and elevated noise levels often associated with low quality cables Do not secure the cables in tight bundles or roll the slack into tight coils Avoid interference from neigh...

Page 6: ...cted and recycled To comply with the WEEE Directive Kramer Electronics has made arrangements with the European Advanced Recycling Network EARN and will cover any costs of treatment recycling and recov...

Page 7: ...rate of 3Gpbs 1 SDI video input and 2 SDI video outputs 1 re clocked looping video output 1 composite video output 2 balanced audio outputs 2 AES 3id audio inputs and 2 AES 3id audio outputs Note Some...

Page 8: ...menu during configuration 2 Menu Navigation Buttons Press the Enter up down left and right buttons to navigate the menu and modify parameters or values see Section 7 2 3 PANEL LOCK Button Press and ho...

Page 9: ...Connect to an SDI signal source 7 LOOP BNC Connector Connect to an SDI acceptor 8 OUT 1 BNC Connector Connect to an SDI acceptor 9 OUT 2 BNC Connector Connect to an SDI acceptor 10 RESET Button Press...

Page 10: ...FC 340 Installing the FC 340 in a Rack 7 5 Installing the FC 340 in a Rack...

Page 11: ...wer and then switch on the power to the other devices Figure 3 Connecting the FC 340 SDI Scaler Embedder Scan Converter To connect the FC 340 as illustrated in the example in Figure 3 1 Connect an SD...

Page 12: ...o the Ethernet RJ 45 connector 6 1 Connecting a Serial Controller to the FC 340 You can connect to the FC 340 via an RS 232 connection using for example a PC To connect to the FC 340 via RS 232 Connec...

Page 13: ...cation of the factory default IP Address of the FC 340 during the initial configuration To configure your PC after connecting the Ethernet port 1 Right click the My Network Places icon on your desktop...

Page 14: ...1 1 to 192 168 1 255 excluding 192 168 1 39 that is provided by your IT department Figure 5 Internet Protocol TCP IP Properties Window 7 Click OK 6 2 2 Connecting to the Ethernet Port via a Network Sw...

Page 15: ...Audio Output This section illustrates how to wire the devices to the balanced audio output A balanced stereo output connection see Figure 6 An unbalanced stereo output connection see Figure 7 Figure 6...

Page 16: ...ed on the following is displayed briefly FC340 KRAMER The device then performs a self test If the test is successful the Menu is displayed as shown below VIDEO OUT AUDIO OUT If there is no button acti...

Page 17: ...used and for 59 94 60Hz resolutions NTSC is used 7 2 Using the Menu The menu is shown on the display when the Enter button is pressed If there is no button activity for approximately 30 seconds the d...

Page 18: ...stics Parameter Description Options Embedding Sets the audio group to embed Group 1 Group 2 Group 3 and Group 4 Off Embedded input AES input Default Embedded input AES Out 1 Embeds the AES audio input...

Page 19: ...5000 RS 232 Baud Displays the baud rate 115200 Parity Displays the parity bit setting none 7 2 5 System Sub menu The parameters in the System sub menu display the device versions and set the LCD displ...

Page 20: ...are locked Pressing any button causes the Locked message to display briefly and the Panel Lock button to flash To unlock the front panel Press and hold the Panel Lock button The button no longer light...

Page 21: ...PTE 259M SMPTE 125M 480i 59 94 ITU R BT 656 5 576i 50 HD SMPTE 292M SMPTE 296M 720p 59 94 60 50 SMPTE 274M 1080i 59 94 60 50 3G SMPTE 424M SMPTE 296M 1080p 59 94 60 50 Max output level 800mVpp 75 Anal...

Page 22: ...ters RS 232 Baud Rate 115 200 Data Bits 8 Stop Bits 1 Parity None Command Format ASCII Example Output 1 to Input 1 AV 1 1 CR Ethernet IP Address 192 168 1 39 Subnet mask 255 255 255 0 Default gateway...

Page 23: ...ing with only one command without addressing start body delimiter Command SP Parameter_1 Parameter_2 CR Commands string formal syntax with commands concatenation and addressing Address Command_1 Param...

Page 24: ...rminal software used to connect over serial ethernet USB port that possible to directly enter all commands characters CR will be entered by Enter key that key send also LF but this char will be ignore...

Page 25: ...y default configuration HELP List of commands End User LDFW Load new firmware User SW Internal MODEL Read device model End User NET DHCP NTDH Set DHCP mode Administrator NET DHCP NTDH Get DHCP mode En...

Page 26: ......

Page 27: ...sit our Web site where updates to this user manual may be found We welcome your questions comments and feedback Web site www kramerelectronics com E mail info kramerel com SAFETY WARNING Disconnect th...