Operating Instructions
OIC 12en Edition 08/2016
7
Operating limits
Technical data
Technical data
Operating limits
Tab. 1 Operating limits
Sound pressure level
Guide values at 1 m distance, 1450 min
-1
, 20 bar
Tab. 2 Sound pressure level
Required NPSH values
Please contact the manufacturer to determine the necessary NPSH values.
Weights
Tab. 3 Weights
Unit
CLC 55
CLC 550
Max. operating pressure
[bar]
63
63
Max. inlet pressure
[bar]
10
10
Max. temperature of pumped liquid
[°C]
60
60
Ambient temperature
[°C]
-10 ... 50
-10 ... 50
Viscosity min. – max.
[mm
2
/s]
3 – 2000000
3 – 2000000
Speed min. – max.
[min
-1
]
50 – 2900
50 – 2900
Unit
CLC 55
CLC 550
Sound pressure level max. ± 3
[db(A)]
57
70
Unit
CLC 55
CLC 550
Pump with free shaft end
[kg]
30
130
Completion
[kg]
17
75